Product Information for Series VQC

VQC1000/VQC2000 MODEL INFORMATION
Series No. of Solenoids Model Flow Characteristics Response Time
msNote2
Weight g
1->4, 2 (P->A, B) 4, 2->5, 3
(A, B->R1, R2)
Standard:
1W
Low Wattage
C[dm3/
(s-bar)]
b Note1
Cv
C[dm3/
(s-bar)]
b Note1
Cv
VQC1000 2 Position Single Metal Seal VQC1100 0.70 0.15 0.16 0.72 0.25 0.18 12 or less 15 or less 64
Rubber Seal VQC1101 0.85 0.20 0.21 1.0 0.30 0.25 15 or less 20 or less
Double Metal Seal VQC1200 0.70 0.15 0.16 0.72 0.25 0.18 10 or less 13 or less 78
Rubber Seal VQC1201 0.85 0.20 0.21 1.0 0.30 0.25 15 or less 20 or less
3 Position Closed
Center
Metal Seal VQC1300 0.68 0.15 0.16 0.72 0.25 0.18 20 or less 26 or less
Rubber Seal VQC1301 0.70 0.20 0.16 0.65 0.42 0.18 25 or less 33 or less
Exhaust Center Metal Seal VQC1400 0.68 0.15 0.16 0.72 0.25 0.18 20 or less 26 or less
Rubber Seal VQC1401 0.70 0.20 0.16 1.0 0.30 0.25 25 or less 33 or less
Pressure Center Metal Seal VQC1500 0.70 0.15 0.16 0.72 0.25 0.18 20 or less 26 or less
Rubber Seal VQC1501 0.85 0.20 0.21 0.65 0.42 0.18 25 or less 33 or less
4 Position Dual 3
Port Valve
Rubber Seal VQC1A01 0.70 0.20 0.16 0.70 0.20 0.16 25 or less 33 or less
VQC1B01 0.70 0.20 0.16 0.70 0.20 0.16 25 or less 33 or less
VQC1C01 0.70 0.20 0.16 0.70 0.20 0.16 25 or less 33 or less
VQC2000 2 Position Single Metal Seal VQC2100 2.0 0.15 0.46 2.6 0.15 0.60 22 or less 29 or less 90
Rubber Seal VQC2101 2.2 0.28 0.55 3.2 0.30 0.80 24 or less 31 or less
Double Metal Seal VQC2200 2.0 0.15 0.46 2.6 0.15 0.60 15 or less 20 or less 110
Rubber Seal VQC2201 2.2 0.28 0.55 3.2 0.30 0.80 20 or less 26 or less
3 Position Closed
Center
Metal Seal VQC2300 2.0 0.15 0.46 2.0 0.18 0.46 29 or less 38 or less
Rubber Seal VQC2301 2.0 0.28 0.49 2.2 0.31 0.60 34 or less 44 or less
Exhaust Center Metal Seal VQC2400 2.0 0.15 0.46 2.6 0.15 0.60 29 or less 38 or less
Rubber Seal VQC2401 2.0 0.28 0.49 3.2 0.30 0.80 34 or less 44 or less
Pressure Center Metal Seal VQC2500 2.4 0.17 0.57 2.0 0.18 0.46 29 or less 38 or less
Rubber Seal VQC2501 3.2 0.28 0.80 2.2 0.31 0.60 34 or less 44 or less
4 Position Dual 3
Port Valve
Rubber Seal VQC2A01 1.8 0.28 0.46 1.8 0.28 0.46 34 or less 44 or less
VQC2B01 1.8 0.28 0.46 1.8 0.28 0.46 34 or less 44 or less
VQC2C01 1.8 0.28 0.46 1.8 0.28 0.46 34 or less 44 or less
Note 1 Values represented in this column are in the following conditions:
VQC1000: Cylinder port size C6 without a back pressure check valve VQC2000: Cylinder port size C8 without a back pressure check valve
Note 2 Values represented in this column are based on JISB8375-1981 (operating with clean air and a supply pressure of 0.5MPa. Equipped with light and surge voltage suppressor. Values vary depending on the pressure as well as the air qualilty.) Values for double types are when the switch is ON.
STANDARD SPECIFICATIONS
Valve Specifications Valve configuration Metal seal Rubber seal
Fluid Air, inert gas
VQC1000/2000 Max. operating pressure 0.7MPa (high pressure type: 1.0MPa)Note 3)
Min. operating pressure Single 0.1MPa 0.15MPa
Double 0.1MPa
3 Position 0.1MPa 0.2MPa
4 Position - 0.15MPa
Proof pressure 1.5MPa
Ambient and fluid temperature -10° to 50° C Note 1)
Lubrication Not required
Manual override Push type/locking type (tool required) optional
Impact resistance/vibration resistance 150/30 m/s2 Note 2)
Enclosure Dust proof (conforms to IP67)
Electrical Specifications Rated coil voltage 24VDC
Allowable voltage fluctuation ±10% of rated voltage
Coil insulation type Equivalent to B type
Power consumption (current) 24VDC 1W DC (42mA), 0.5W DC (21mA)
Note 1 Use dry air to prevent condensation at low temperatures.
Note 2 Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed one time each in the axial and right angle directions of the main valve and armature, for both energized and de-energized states.
Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 2000Hz. Test was performed in the axial and right angle directions of the main valve and armature for both energized and de-energized states.
Note 3 Metal seal type only.
MANIFOLD SPECIFICATIONS
VQC1000/2000 MANIFOLD SPECIFICATIONS
Series Base Model Connection Type Piping Specifications Note 2)Applicable Stations Applicable Solenoid Valves 5-Station Weight (g)
Port Direction Port Size Note 1)
Side 1, 3 (P, R) 2, 4 (A, B)
VQC1000 VV5QC11- F Kit: D-sub connector C8 (for ø8) [Options Direct outlet with built-in silencer] C3 (for ø3.2)
C4 (for ø4)C6 (for ø6)
M5 threads
(F and P Kits 1 to 12 stations)
(T Kit 1 to 10 stations)(S Kit 1 to 8 stations: EX500; 1 to 12 stations: EX250)
VQC100-5 VQC101-5 628 (Single) (759 Double, 3P)
P Kit: Flat ribbon cable
T Kit: Terminal block box
S Kit: Serial transmission
VQC2000 VV5QC21- F Kit: D-sub connector C10 (for ø10) [Options Direct outlet with built-in silencer] C4 (for ø4)
C6 (for ø6)C8 (for ø8)
VQC200-5 VQC201-5 1051 (Single) 1144 (Double, 3P)
P Kit: Flat ribbon cable
T Kit: Terminal block box
S Kit: Serial transmission
Note 1 One-touch fittings in inch sizes are also available
Note 2 An optional specification for special wiring is available to increase the maximum number of stations.
VQC4000 VALVE SPECIFICATIONS
Valve
specifications
Valve Configuration Metal Seal Rubber Seal
Fluid Air/Inert gas
Maximum operating pressure(Note1) 1.0MPa (0.7MPa)
Minimum operating pressure Single 0.15MPa 0.2MPa
Double 0.15MPa
3-Position 0.15MPa 0.2MPa
Proof pressure 1.5MPa
Ambient and fluid temperature -10° to 50°C(Note2)
Lubrication Not required
Manual override Push type/Locking type (tool required) optional
Impact resistance/Vibration resistance 150/30 m/s2(Note3)
Enclosure Dust proof (conforms to IP67)
Electrical
specifications
Rated coil voltage 24VDC
Allowable voltage fluctuation ±10% of rated voltage
Coil insulation type Equivalent to B type
Power consumption (current) 24VDC 1W DC (42mA), 0.5W DC (21mA)
Note 1:  Values in (  ) are for the low wattage (0.5W) specification.
Note 2:  Use dry air to prevent condensation at low temperatures.
Note 3:  Impact resistance:      No malfunction resulted from the impact tester.  The test was performed one time each in the axial and right angle directions
                                               of the main valve and armature, for both energized and de-energized states.
             Vibration resistance:  No malfunction occurred in a one-sweep test between 8.3 and 2000Hz.  Test was performed in the axial and right angle
                                               directions of the main valve and armature for both energized and de-energized states. 
MODEL INFORMATION
Number of
Solenoids
Model Flow Characteristics Response
TimeNote2ms
Weight
g
1→4, 2 (P→A, B) 4, 2→5, 3 (A, B→R1, R2) Standard:
1W
Low
Wattage
C[dm3/(s·bar)] b Cv C[dm3/(s·bar)] b Cv
2
Position
Single Metal seal VQC4100 6.2 0.19 1.5 6.9 0.17 1.7 20 or less 22 or less 230
Rubber seal VQC4101 7.2 0.43 2.1 7.3 0.38 2.0 25 or less 27 or less
Double Metal seal VQC4200 6.2 0.19 1.5 6.9 0.17 1.7 12 or less 12 or less 260
Rubber seal VQC4201 7.2 0.43 2.1 7.3 0.38 2.0 15 or less 15 or less
3
Position
Closed
center
Metal seal VQC4300 5.9 0.23 1.5 6.3 0.18 1.6 45 or less 47 or less 280
Rubber seal VQC4301 7.0 0.34 1.9 6.4 0.42 1.9 50 or less 52 or less
Exhaust
center
Metal seal VQC4400 6.2 0.18 1.5 6.9 0.17 1.7 45 or less 47 or less
Rubber seal VQC4401 7.0 0.38 1.9 7.3 0.38 2.0 50 or less 52 or less
Pressure
center
Metal seal VQC4500 6.2 0.18 1.9 6.4 0.18 1.6 45 or less 47 or less
Rubber seal VQC4501 7.0 0.38 1.9 7.1 0.38 2.0 50 or less 52 or less
Perfect Metal seal VQC4600 2.7 - - 3.7 - - 55 or less 57 or less 500
Rubber seal VQC4601 2.8 - - 3.9 - - 62 or less 64 or less
Note 1:  Values based on cylinder port size Rc 3/8
Note 2:  Values in this column are based on JISB8375-1981 (operating with clean air and a supply pressure of 0.5MPa.  Equipped with light and surge voltage
             suppressor.  Values vary depending on the pressure as well as the air quality.) Values for double types are when the switch is ON.
MANIFOLD SPECIFICATIONS
VV5QC41-**S*, DECENTRALIZED SERIAL WIRING (EX500) SPECIFICATIONS
Series Base Model S Kit Type Piping Specifications Applicable
Stations2
Applicable
Solenoid
Valves
5-Station
Weight
(g)
Port
Direction
Port Size1
1, 3 (P, R) 2, 4 (A, B)
VQC4000 VV5QC41- SD0A: Serial kit w/o SI unit
SDA1:  Serial kit for Remote I/O
SDA2:  Serial kit PROFIBUS-DP compatible
Side P:Rc 1/2
R:Rc 3/4
C8 (for 8)
C10 (for 10)
C12 (for 12)
Rc 1/4
Rc 3/8
1~8 (16) VQC400-5
VQC401-5
4150
·S kit (without unit)
·Solenoid weight is not included
Bottom Rc 1/4
Note 1:  One touch fittings in inch sizes are also available.
Note 2:  An optional specification for special wiring is available to increase the maximum number of stations.
VV5QC41-**S*, I/O SERIAL TRANSMISSION UNIT (EX250) SPECIFICATIONS
Series Base Model S Kit Type Piping Specifications Applicable
Stations2
Applicable
Solenoid
Valves
5-Station
Weight
(g)
Port
Direction
Port Size1
1, 3 (P, R) 2, 4 (A, B)
VQC4000 VV5QC41- SD0: Serial kit w/o SI unit
SDN:  Serial kit PROFIBUS-DP compatible
SDQ:  Serial kit DeviceNet compatible
SDV: CC-link compatible
Side P:Rc 1/2
R:Rc 3/4
C8 (for 8)
C10 (for 10)
C12 (for 12)
Rc 1/4
Rc 3/8
1~12 (16) VQC400-5
VQC401-5
4150
·S kit (without unit)
·Solenoid weight is not included
Bottom Rc 1/4
Note 1:  One touch fittings in inch sizes are also available.
Note 2:  An optional specification for special wiring is available to increase the maximum number of stations.
VV5QC41-**TD0, TERMINAL BLOCK BOX SPECIFICATIONS
Series Base Model T Kit Type Piping Specifications Applicable
Stations2
Applicable
Solenoid
Valves
5-Station
Weight
(g)
Port
Direction
Port Size1
1, 3 (P, R) 2, 4 (A, B)
VQC4000 VV5QC41- TD0: Terminal block box Side P:Rc 1/2
R:Rc 3/4
C8 (for 8)
C10 (for 10)
C12 (for 12)
Rc 1/4
Rc 3/8
1~10 (16) VQC400-5
VQC401-5
4150
·Solenoid weight is not included
Bottom Rc 1/4
Note 1:  One touch fittings in inch sizes are also available.
Note 2:  An optional specification for special wiring is available to increase the maximum number of stations.
VV5QC41-**FD*, D-SUB CONNECTOR SPECIFICATIONS
Series Base Model F Kit Type Piping Specifications Applicable
Stations2
Applicable
Solenoid
Valves
5-Station
Weight
(g)
Port
Direction
Port Size1
1, 3 (P, R) 2, 4 (A, B)
VQC4000 VV5QC41- FD0: D-sub connector (25P) w/o cable
FD1: D-sub connector (25P) w/1.5m cable
FD2: D-sub connector (25P) w/3.0m cable
FD3: D-sub connector (25P) with 5.0m cable
Side P:Rc 1/2
R:Rc 3/4
C8 (for 8)
C10 (for 10)
C12 (for 12)
Rc 1/4
Rc 3/8
1~12 (16) VQC400-5
VQC401-5
4150
·Solenoid weight is not included
Bottom Rc 1/4
Note 1:  One touch fittings in inch sizes are also available.
Note 2:  An optional specification for special wiring is available to increase the maximum number of stations.
VV5QC41-**PD* FLAT RIBBON CABLE SPECIFICATIONS
Series Base Model P Kit Type Piping Specifications Applicable
Stations2
Applicable
Solenoid
Valves
5-Station
Weight
(g)
Port
Direction
Port Size1
1, 3 (P, R) 2, 4 (A, B)
VQC4000 VV5QC41- PD0: Flat ribbon cable (26P) w/o cable
PD1: Flat ribbon cable (26P) w/1.5m cable
PD2: Flat ribbon cable (26P) w/3.0m cable
PD3: Flat ribbon cable (26P) w/5.0m cable
PDC: Flat ribbon cable (20P) w/o cable
Side P:Rc 1/2
R:Rc 3/4
C8 (for 8)
C10 (for 10)
C12 (for 12)
Rc 1/4
Rc 3/8
1~12 (16)
PDC kit 1~9 (16)
VQC400-5
VQC401-5
4150
·Solenoid weight is not included
Bottom Rc 1/4
Note 1:  One touch fittings in inch sizes are also available.
Note 2:  An optional specification for special wiring is available to increase the maximum number of stations.
VV5QC41-**L LEAD WIRE SPECIFICATIONS
Series Base Model L Kit Type Piping Specifications Applicable
Stations2
Applicable
Solenoid
Valves
5-Station
Weight
(g)
Port
Direction
Port Size1
1, 3 (P, R) 2, 4 (A, B)
VQC4000 VV5QC41- LD0: Lead wire w/0.6m lead wire
LD1:  Lead wire w/1.5m lead wire
LD2:  Lead wire w/3.0m lead wire
Side P:Rc 1/2
R:Rc 3/4
C8 (for 8)
C10 (for 10)
C12 (for 12)
Rc 1/4
Rc 3/8
1~12 (16) VQC400-5
VQC401-5
4150
·Solenoid weight is not included
Bottom Rc 1/4
Note 1:  One touch fittings in inch sizes are also available.
Note 2:  An optional specification for special wiring is available to increase the maximum number of stations.
VV5QC41-**M MULTI-CONNECTOR SPECIFICATIONS
Series Base Model M Kit Type Piping Specifications Applicable
Stations2
Applicable
Solenoid
Valves
5-Station
Weight
(g)
Port
Direction
Port Size1
1, 3 (P, R) 2, 4 (A, B)
VQC4000 VV5QC41- MD0: Multi-connector w/o cable
MD1: Multi-connector w/1.5m cable
MD2: Multi-connector w/3.0m cable
MD3: Multi-connector w/5.0m cable
Side P:Rc 1/2
R:Rc 3/4
C8 (for 8)
C10 (for 10)
C12 (for 12)
Rc 1/4
Rc 3/8
1~12 (16) VQC400-5
VQC401-5
4150
·Solenoid weight is not included
Bottom Rc 1/4
Note 1:  One touch fittings in inch sizes are also available.
Note 2:  An optional specification for special wiring is available to increase the maximum number of stations.

Last Updated on 9/5/01